开云在线官方

网站公告:

新闻中心

开云在线官方(中国)有限公司官网

电话:0531-69951198

邮箱:jingtuolt@163.com

传真:0531-69951198

地址:济南市历城区祝甸北路2号院

网址://keonnected.com

企业动态

当前位置:首页 - 新闻中心 - 企业动态 - 对气体增压泵停止运行问题

对气体增压泵停止运行问题的解决方案

发布时间:2019-07-03 19:18:50   发布人://keonnected.com
今天针对气体增压泵停止运行问题,进行检查,未发现问题原因,仍无法运行。
Today, for the gas booster pump stop operation problem, inspection, found no cause of the problem, still unable to run.
检测内容如下:
The detection contents are as follows:
1.驱动进气检测。
1. Drive air intake detection.
2.监测管线检查。
2. Monitoring pipeline inspection.
3.增压泵缸体检查。
3. Check the cylinder body of booster pump.
4.驱动气换向阀检查。
4. Inspection of driving air reversing valve.
驱动进气检查:
Drive air intake check:
①将2#GCU增压泵切换到问题增压泵,确认:增压泵进出气管线阀门打开,驱动 气阀门打开,监测管线阀门打开。投用驱动气(仪表风@6bar),增压泵未动作。
① Switch the 2 ා GCU booster pump to the problem booster pump, and confirm that: the inlet and outlet gas pipeline valve of booster pump is opened, the driving gas valve is opened, and the monitoring pipeline valve is opened. When the driving gas (instrument air @ 6bar) was put into operation, the booster pump did not operate.
②拆下four-way valve(换向阀)后,打开驱动管线阀门,有明显气体进入。说明驱动气管线正常。
② After removing the four way valve, open the drive line valve and there is obvious gas entering. It indicates that the driving gas pipeline is normal.
2.监测管线检查:通入工艺气及氮气后,监测气变送器示值未发生变化。
2. Inspection of monitoring pipeline: the indication value of monitoring gas transmitter did not change after process gas and nitrogen were introduced.
3.缸体检查:据用户供的信息,增压泵停止工作前,声音异常,明显高于正常工作时。  经询问没有听到金属摩擦的声音。现场未发现缸体因活塞摩擦产生变形或颜色变化。
3. Cylinder block inspection: according to the information provided by the user, before the booster pump stops working, the sound is abnormal, which is obviously higher than that during normal operation. After inquiry, no metal friction was heard. No deformation or color change of cylinder block due to piston friction was found on site.
4.驱动气换向阀检查:
4. Inspection of driving air reversing valve:
拆下换向阀之后,检查未发现被污染痕迹。酒精清洗后回装。回装过程中手指驱动 换向阀芯,没有明显卡滞感觉,阀芯运行平顺。
After removing the change-over valve, no contamination was found. Replace the alcohol after cleaning. During the process of reassembly, the finger drives the reversing valve core, and there is no obvious jamming feeling, and the valve core runs smoothly.
新闻推荐:
空气增压泵的使用优势大揭秘! 2022-07-05
气体增压泵的生产要注意哪些环节? 2022-06-27
选择气动增压泵要从哪些方面考虑? 2022-06-19
大流量气体增压系统的使用特点 2022-06-10
气体增压泵一直被长期使用的原因? 2022-06-02
气体增压泵和液体增压泵有什么区别? 2022-05-27
气体增压泵能取代传统的机械泵、液压泵 2022-05-15
增压泵的安装必要事项! 2022-05-10
增压泵的使用维护非常简单! 2022-04-28
气体增压泵的使用方法及注意事项: 2022-04-20

13188935873